Code Rule 56 Related Helpful Information
Code Rule 56 – Asbestos (effective March 21, 2007)
On March 21, 2007, the New York State Department of Labor adopted corrections for Code Rule 56 to incorporate Federal Standards and to correct typographical errors. You can view or print a copy of Code Rule 56 (open in a new window) in PDF format.
New - On April 8, 2011 the New York State Department of Health Environmental Laboratory Approval Program (ELAP) issued a list of frequently asked questions and answers regarding asbestos air/bulk sample collection and analysis methodologies.
Below is a link to the document:
Noteworthy issues include Q&As #5, 8 and 10 and regarding bulk sample analysis methodologies including analyzing suspect ceiling tile samples containing cellulose by NOB methodology, surface dust/residue sample collection/analysis, and treating vermiculite insulation as ACM because currently no reliable bulk analysis methodology exists for vermiculite.
2011 Amended Code Rule 56 Rule Making
We expect to revise Code Rule 56 again in 2011.
The main purpose of the revision is to clarify fire/life safety concerns at asbestos projects by making sure that:
-
Egress is not obstructed
-
The existing fire protection system is maintained and fully working
-
A plan exists for emergency evacuation
Also, asbestos abatement contractors must use fire-retardent materials to construct the asbestos project containment enclosure (sheathing, barriers, and decontamination system enclosure). This way the materials do not contribute greatly to the added fire load in the building or structure.
DOL will add a requirement to install negative air ventilation system disconnect switch(es) below any asbestos project containment enclosures that cover:
- An entire floor
- An area greater than 15,000 sq. ft. on any given floor
This allows for shut off of this equipment during a fire. These fire safety revisions reflect lessons learned from the fatal fire at 130 Liberty Street in New York City.
In addition, the revision adds a requirement for review and acceptance of asbestos project documents regarding fire/life safety compliance with building and fire code regulations for implementation of the asbestos project, The review must be by a person currently certified with a CEO level of training by New York State Department of State or a registered design professional.
This revision also incorporates:
- Changes in the statue to address successor asbestos abatement companies
- Clarifications from the current guidance document
-
All existing applicable variances (as well as ones under consideration)
Variances
Where there are practical difficulties in complying with Code Rule 56, DOL may provide relief in the form of a variance decision. The Asbestos Variances Fact Sheet (open in a new window) explains the types of variances that DOL issues:
- Applicable Variance
- Blanket Variance
- Site-Specific Variance
- Multi-Site Variance
Further:
- A currently trained and DOL-certified Project Designer (who works for a DOL-licensed asbestos contractor) must prepare and submit each variance petition
- All new Site-Specific Variance decisions will remain in effect one year from the date of issuance (unless otherwise stated)
- DOL has terminated all Applicable Variances, Blanket Variances and Multi-Site Variances based upon the November 9, 1994 version or earlier versions of Code Rule 56
Existing Applicable Variances
- All Applicable Variances will be numbered consecutively as AV-A-#.
- Existing Applicable Variances are listed below:
- Controlled Demolition of Municipally-Owned Vacant Residential Buildings/Structures up to 3-Stories in Height AV-A-1 (open in a new window)
- Negative Air Ventilation Exhaust Greater Than 25 Foot in Length AV-A-2 (open in a new window)-
- Non-friable ACM Floor Covering Mastic removal Using Chemical Methods along with Low-speed Floor Buffers AV-A-3 (open in a new window)
- Removal or Cleanup of Intact Minor Size Non-friable ACM Floor Tile AV-A-4 (open in a new window)
Compliance Assistance Documents
The Department of Labor has developed the following Compliance Assistance Documents to supplement Code Rule 56:
- Guidance Document for (v2.0) on Amended Industrial Code Rule 56 AGD-v2.0 (open in a new window)
- Asbestos Variances Fact Sheet AFS-1 (open in a new window)
The Guidance Document is in a question and answer format to help you apply Code Rule 56. DOL revises this document periodically to add new questions and appropriate responses as they develop.
You can submit questions or comments for the Guidance Document to the following email: labor.sm.sh.esu@labor.state.ny.us.
Code Rule 56 Presentations:
Asbestos Control Bureau
The Asbestos Control Bureau enforces Code Rule 56.
If you have any more questions or need further help regarding the Code Rule or any other asbestos matter, please contact your Asbestos District Office from the list below or call the Engineering Services Unit at (518) 457-1536.
ASBESTOS CONTROL BUREAU DISTRICT OFFICES
ALBANY DISTRICT
Counties - Albany, Clinton, Columbia, Dutchess, Essex, Green, Orange, Putnam, Rockland, Rensselaer, Saratoga, Schenectady, Schoharie, Ulster, Warren, Washington
State Office Campus, Room 157, Albany, NY 12240
(518) 457-1255 (FAX) (518) 485-8054
(518) 457-2072 (FAX)(518) 485-1740 (Field Office)
BUFFALO DISTRICT
Counties - Cattaraugus, Chautauqua, Erie, Genesee, Livingston, Monroe, Niagara, Ontario, Orleans, Wayne, Wyoming, Yates
65 Court Street, Rm. 405, Buffalo, NY 14202
(716) 847-7601 (716) 847-7126 (FAX) (716) 847-7138
NEW YORK CITY DISTRICT
Counties - Bronx, Kings, Nassau, New York, Queens, Richmond, Suffolk, Westchester
One Hudson Square, 75 Varick Street, 7th Floor, New York, NY 10013
(212) 775-3538 (FAX) (212) 775-3527
SYRACUSE DISTRICT
Counties - Allegany, Broome, Cayuga, Chemung, Chenango, Cortland, Delaware, Franklin, Fulton, Hamilton, Herkimer, Jefferson, Lewis, Madison, Montgomery, Oneida, Onondaga, Oswego, Otsego, St. Lawrence, Schuyler, Seneca, Steuben, Sullivan, Tioga, Tompkins
450 S. Salina Street, Syracuse, NY 13202
(315) 479-3215 (FAX) (315) 479-3451
ENGINEERING SERVICES UNIT
State Office Campus, Room 154, Albany, NY 12240
(518) 457-1536 (FAX) (518) 457-1301